smartctl version 5.33 [i686-pc-linux-gnu] Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: MAXTOR 4K040H2 Serial Number: 572200516888 Firmware Version: A08.1500 User Capacity: 40,037,760,000 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 5 ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1 Local Time is: Sat Jul 29 18:09:05 2006 ADT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 44) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 26) minutes. SMART Attributes Data Structure revision number: 11 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 087 086 020 Pre-fail Always - 1677 4 Start_Stop_Count 0x0032 099 099 008 Old_age Always - 1101 5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail Always - 2 7 Seek_Error_Rate 0x000b 100 093 023 Pre-fail Always - 0 9 Power_On_Hours 0x0012 096 096 001 Old_age Always - 2755 10 Spin_Retry_Count 0x0026 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 099 099 008 Old_age Always - 955 13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail Always - 0 194 Temperature_Celsius 0x0022 089 086 042 Old_age Always - 30 195 Hardware_ECC_Recovered 0x001a 100 018 000 Old_age Always - 18479267 196 Reallocated_Event_Count 0x0010 100 100 020 Old_age Offline - 0 197 Current_Pending_Sector 0x0032 100 100 020 Old_age Always - 1 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x001a 118 118 000 Old_age Always - 82 SMART Error Log Version: 1 ATA Error Count: 77 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 77 occurred at disk power-on lifetime: 2755 hours (114 days + 19 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 01 1b 10 e9 e1 Error: UNC at LBA = 0x01e9101b = 32051227 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 01 01 1b 10 e9 e1 e9 00:01:26.100 READ MULTIPLE c4 01 02 1a 10 e9 e1 e9 00:01:22.057 READ MULTIPLE c4 01 03 19 10 e9 e1 e9 00:01:18.015 READ MULTIPLE c4 01 04 18 10 e9 e1 e9 00:01:13.974 READ MULTIPLE e7 01 00 00 00 00 00 e9 00:01:13.964 FLUSH CACHE Error 76 occurred at disk power-on lifetime: 2755 hours (114 days + 19 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 02 1a 10 e9 e1 Error: UNC at LBA = 0x01e9101a = 32051226 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 01 02 1a 10 e9 e1 e9 00:01:22.057 READ MULTIPLE c4 01 03 19 10 e9 e1 e9 00:01:18.015 READ MULTIPLE c4 01 04 18 10 e9 e1 e9 00:01:13.974 READ MULTIPLE e7 01 00 00 00 00 00 e9 00:01:13.964 FLUSH CACHE c5 00 08 84 73 13 e0 13 00:01:13.963 WRITE MULTIPLE Error 75 occurred at disk power-on lifetime: 2755 hours (114 days + 19 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 03 19 10 e9 e1 Error: UNC at LBA = 0x01e91019 = 32051225 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 01 03 19 10 e9 e1 e9 00:01:18.015 READ MULTIPLE c4 01 04 18 10 e9 e1 e9 00:01:13.974 READ MULTIPLE e7 01 00 00 00 00 00 e9 00:01:13.964 FLUSH CACHE c5 00 08 84 73 13 e0 13 00:01:13.963 WRITE MULTIPLE e7 01 00 00 00 00 00 e9 00:01:13.944 FLUSH CACHE Error 74 occurred at disk power-on lifetime: 2755 hours (114 days + 19 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 04 18 10 e9 e1 Error: UNC at LBA = 0x01e91018 = 32051224 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 01 04 18 10 e9 e1 e9 00:01:13.974 READ MULTIPLE e7 01 00 00 00 00 00 e9 00:01:13.964 FLUSH CACHE c5 00 08 84 73 13 e0 13 00:01:13.963 WRITE MULTIPLE e7 01 00 00 00 00 00 e9 00:01:13.944 FLUSH CACHE c5 00 a0 e4 72 13 e0 13 00:01:13.935 WRITE MULTIPLE Error 73 occurred at disk power-on lifetime: 2755 hours (114 days + 19 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 05 1b 10 e9 e1 Error: UNC at LBA = 0x01e9101b = 32051227 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 01 05 1b 10 e9 e1 e9 00:01:09.864 READ MULTIPLE c4 01 06 1a 10 e9 e1 e9 00:01:05.810 READ MULTIPLE c4 01 07 19 10 e9 e1 e9 00:01:01.768 READ MULTIPLE c4 01 08 18 10 e9 e1 e9 00:00:57.734 READ MULTIPLE c4 00 08 10 10 e9 e1 00 00:00:57.733 READ MULTIPLE SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 2667 - # 2 Short offline Completed without error 00% 2660 - Device does not support Selective Self Tests/Logging