hdb.txt 15/5/09 smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.8 family Device Model: ST3200826A Serial Number: 3ND2DJWQ Firmware Version: 3.03 User Capacity: 200,049,647,616 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Fri May 15 11:47:56 2009 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 67) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 053 052 006 Pre-fail Always - 13454619 3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 43 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 477947525 9 Power_On_Hours 0x0032 074 074 000 Old_age Always - 22933 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 44 194 Temperature_Celsius 0x0022 045 047 000 Old_age Always - 45 (0 15 0 0) 195 Hardware_ECC_Recovered 0x001a 053 052 000 Old_age Always - 13454619 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 196 000 Old_age Always - 236 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 236 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 236 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:22:34.262 READ DMA EXT 25 00 08 00 00 00 f0 00 00:22:33.847 READ DMA EXT 10 00 ff 00 00 00 f0 00 00:22:33.846 RECALIBRATE [OBS-4] 25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT 25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT Error 235 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:22:34.262 READ DMA EXT 10 00 ff 00 00 00 f0 00 00:22:33.847 RECALIBRATE [OBS-4] 25 00 08 00 00 00 f0 00 00:22:33.846 READ DMA EXT 25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT ef 02 00 00 00 00 f0 00 00:22:33.844 SET FEATURES [Enable write cache] Error 234 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:22:34.262 READ DMA EXT 25 00 08 00 00 00 f0 00 00:22:33.847 READ DMA EXT ef 02 00 00 00 00 f0 00 00:22:33.846 SET FEATURES [Enable write cache] 27 00 00 00 00 00 f0 00 00:22:33.844 READ NATIVE MAX ADDRESS EXT c6 00 00 00 00 00 f0 00 00:22:33.844 SET MULTIPLE MODE Error 233 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:22:05.509 READ DMA EXT ef 02 00 00 00 00 f0 00 00:22:33.847 SET FEATURES [Enable write cache] 27 00 00 00 00 00 f0 00 00:22:33.846 READ NATIVE MAX ADDRESS EXT c6 00 00 00 00 00 f0 00 00:22:33.844 SET MULTIPLE MODE 10 00 ff 00 00 00 f0 00 00:22:33.844 RECALIBRATE [OBS-4] Error 232 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:00:35.850 READ DMA EXT 25 00 08 00 00 00 f0 00 00:00:34.254 READ DMA EXT 10 00 ff 00 00 00 f0 00 00:00:42.468 RECALIBRATE [OBS-4] 25 00 08 00 00 00 f0 00 00:00:42.035 READ DMA EXT 25 00 08 00 00 00 f0 00 00:00:42.035 READ DMA EXT SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. hdb.txt 23-06-09 smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.8 family Device Model: ST3200826A Serial Number: 3ND2DJWQ Firmware Version: 3.03 User Capacity: 200,049,647,616 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Tue Jun 23 14:39:46 2009 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 67) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 058 052 006 Pre-fail Always - 22053062 3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 45 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 543121377 9 Power_On_Hours 0x0032 073 073 000 Old_age Always - 23856 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 46 194 Temperature_Celsius 0x0022 043 047 000 Old_age Always - 43 (0 15 0 0) 195 Hardware_ECC_Recovered 0x001a 058 052 000 Old_age Always - 22053062 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 196 000 Old_age Always - 240 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 240 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 240 occurred at disk power-on lifetime: 23102 hours (962 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:00:35.255 READ DMA EXT 25 00 08 00 00 00 f0 00 00:00:33.695 READ DMA EXT 10 00 ff 00 00 00 f0 00 00:00:41.886 RECALIBRATE [OBS-4] 25 00 08 00 00 00 f0 00 00:00:41.453 READ DMA EXT 25 00 08 00 00 00 f0 00 00:00:41.452 READ DMA EXT Error 239 occurred at disk power-on lifetime: 23102 hours (962 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:00:35.255 READ DMA EXT 10 00 ff 00 00 00 f0 00 00:00:33.695 RECALIBRATE [OBS-4] 25 00 08 00 00 00 f0 00 00:00:23.913 READ DMA EXT 25 00 08 00 00 00 f0 00 00:00:41.453 READ DMA EXT ef 02 00 00 00 00 f0 00 00:00:41.452 SET FEATURES [Enable write cache] Error 238 occurred at disk power-on lifetime: 23102 hours (962 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:00:35.255 READ DMA EXT 25 00 08 00 00 00 f0 00 00:00:33.695 READ DMA EXT ef 02 00 00 00 00 f0 00 00:00:23.913 SET FEATURES [Enable write cache] 27 00 00 00 00 00 f0 00 00:00:12.146 READ NATIVE MAX ADDRESS EXT c6 00 00 00 00 00 f0 00 00:00:12.146 SET MULTIPLE MODE Error 237 occurred at disk power-on lifetime: 23102 hours (962 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:00:35.255 READ DMA EXT ef 02 00 00 00 00 f0 00 00:00:33.695 SET FEATURES [Enable write cache] 27 00 00 00 00 00 f0 00 00:00:23.913 READ NATIVE MAX ADDRESS EXT c6 00 00 00 00 00 f0 00 00:00:12.146 SET MULTIPLE MODE 10 00 ff 00 00 00 f0 00 00:00:12.146 RECALIBRATE [OBS-4] Error 236 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 f0 00 00:22:34.262 READ DMA EXT 25 00 08 00 00 00 f0 00 00:22:33.847 READ DMA EXT 10 00 ff 00 00 00 f0 00 00:22:33.846 RECALIBRATE [OBS-4] 25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT 25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 22944 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. hdc.txt 15-5-09 smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.8 family Device Model: ST3200826A Serial Number: 3ND2DJ2K Firmware Version: 3.03 User Capacity: 200,049,647,616 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Fri May 15 11:48:07 2009 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 67) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 069 048 006 Pre-fail Always - 144987126 3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 43 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 488018393 9 Power_On_Hours 0x0032 074 074 000 Old_age Always - 23001 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 44 194 Temperature_Celsius 0x0022 038 043 000 Old_age Always - 38 (0 16 0 0) 195 Hardware_ECC_Recovered 0x001a 069 048 000 Old_age Always - 144987126 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 196 000 Old_age Always - 236 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 236 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 236 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:22:36.287 READ DMA EXT 25 00 08 00 00 00 e0 00 00:22:35.855 READ DMA EXT 10 00 ff 00 00 00 e0 00 00:22:35.444 RECALIBRATE [OBS-4] 25 00 08 00 00 00 e0 00 00:22:35.444 READ DMA EXT 25 00 08 00 00 00 e0 00 00:22:35.443 READ DMA EXT Error 235 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:22:36.287 READ DMA EXT 10 00 ff 00 00 00 e0 00 00:22:35.855 RECALIBRATE [OBS-4] 25 00 08 00 00 00 e0 00 00:22:35.444 READ DMA EXT 25 00 08 00 00 00 e0 00 00:22:35.444 READ DMA EXT ef 02 00 00 00 00 e0 00 00:22:35.443 SET FEATURES [Enable write cache] Error 234 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:22:05.295 READ DMA EXT 25 00 08 00 00 00 e0 00 00:22:35.855 READ DMA EXT ef 02 00 00 00 00 e0 00 00:22:35.444 SET FEATURES [Enable write cache] 27 00 00 00 00 00 e0 00 00:22:35.444 READ NATIVE MAX ADDRESS EXT c6 00 00 00 00 00 e0 00 00:22:35.443 SET MULTIPLE MODE Error 233 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:22:05.295 READ DMA EXT ef 02 00 00 00 00 e0 00 00:22:05.289 SET FEATURES [Enable write cache] 27 00 00 00 00 00 e0 00 00:22:35.444 READ NATIVE MAX ADDRESS EXT c6 00 00 00 00 00 e0 00 00:22:35.444 SET MULTIPLE MODE 10 00 ff 00 00 00 e0 00 00:22:35.443 RECALIBRATE [OBS-4] Error 232 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:00:39.953 READ DMA EXT 25 00 08 00 00 00 e0 00 00:00:35.912 READ DMA EXT 10 00 ff 00 00 00 e0 00 00:00:34.326 RECALIBRATE [OBS-4] 25 00 08 00 00 00 e0 00 00:00:44.450 READ DMA EXT 25 00 08 00 00 00 e0 00 00:00:44.018 READ DMA EXT SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. hdc.txt 23-06-09 smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.8 family Device Model: ST3200826A Serial Number: 3ND2DJ2K Firmware Version: 3.03 User Capacity: 200,049,647,616 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Tue Jun 23 14:55:10 2009 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 67) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 058 048 006 Pre-fail Always - 186762971 3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 45 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 553298211 9 Power_On_Hours 0x0032 073 073 000 Old_age Always - 23924 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 46 194 Temperature_Celsius 0x0022 039 043 000 Old_age Always - 39 (0 16 0 0) 195 Hardware_ECC_Recovered 0x001a 058 048 000 Old_age Always - 186762971 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 196 000 Old_age Always - 240 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 240 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 240 occurred at disk power-on lifetime: 23169 hours (965 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:00:39.246 READ DMA EXT 25 00 08 00 00 00 e0 00 00:00:35.193 READ DMA EXT 10 00 ff 00 00 00 e0 00 00:00:33.633 RECALIBRATE [OBS-4] 25 00 08 00 00 00 e0 00 00:00:43.700 READ DMA EXT 25 00 08 00 00 00 e0 00 00:00:43.268 READ DMA EXT Error 239 occurred at disk power-on lifetime: 23169 hours (965 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:00:39.246 READ DMA EXT 10 00 ff 00 00 00 e0 00 00:00:35.193 RECALIBRATE [OBS-4] 25 00 08 00 00 00 e0 00 00:00:33.633 READ DMA EXT 25 00 08 00 00 00 e0 00 00:00:23.876 READ DMA EXT ef 02 00 00 00 00 e0 00 00:00:43.268 SET FEATURES [Enable write cache] Error 238 occurred at disk power-on lifetime: 23169 hours (965 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:00:39.246 READ DMA EXT 25 00 08 00 00 00 e0 00 00:00:35.193 READ DMA EXT ef 02 00 00 00 00 e0 00 00:00:33.633 SET FEATURES [Enable write cache] 27 00 00 00 00 00 e0 00 00:00:23.876 READ NATIVE MAX ADDRESS EXT c6 00 00 00 00 00 e0 00 00:00:12.208 SET MULTIPLE MODE Error 237 occurred at disk power-on lifetime: 23169 hours (965 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:00:39.246 READ DMA EXT ef 02 00 00 00 00 e0 00 00:00:35.193 SET FEATURES [Enable write cache] 27 00 00 00 00 00 e0 00 00:00:33.633 READ NATIVE MAX ADDRESS EXT c6 00 00 00 00 00 e0 00 00:00:23.876 SET MULTIPLE MODE 10 00 ff 00 00 00 e0 00 00:00:12.208 RECALIBRATE [OBS-4] Error 236 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 00 00 00 e0 00 00:22:36.287 READ DMA EXT 25 00 08 00 00 00 e0 00 00:22:35.855 READ DMA EXT 10 00 ff 00 00 00 e0 00 00:22:35.444 RECALIBRATE [OBS-4] 25 00 08 00 00 00 e0 00 00:22:35.444 READ DMA EXT 25 00 08 00 00 00 e0 00 00:22:35.443 READ DMA EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 23078 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.