eventd.log: --- cut 2006-10-02 01:35:37,515 DEBUG [EventHandlerPool-fiber1] EventWriter: EventWriter: DBID: 68772 2006-10-02 01:35:37,524 DEBUG [EventHandlerPool-fiber1] EventWriter: SUCCESSFULLY added uei.opennms.org/vendor/alcatel/cms/systemAlarm related data into the EVENTS table 2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventWriter: EventWriter finished for : uei.opennms.org/vendor/alcatel/cms/systemAlarm 2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Event to be broadcasted: uei.opennms.org/vendor/alcatel/cms/systemAlarm 2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Queued event to listener: Actiond:BroadcastEventProcessor 2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Queued event to listener: Notifd:BroadcastEventProcessor 2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Queued event to listener: Scriptd:BroadcastEventProcessor 2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Queued event to listener: OpenNMS.Poller.DefaultPollContext 2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: No listener interested in event: uei.opennms.org/vendor/alcatel/cms/systemAlarm 2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] AlarmWriter: AlarmWriter: uei 'uei.opennms.org/vendor/alcatel/cms/systemAlarm' marked as 'doNotPersist' or reductionKey is null. --- cut --- trapd.log --- cut 2006-10-02 01:37:03,557 DEBUG [TrapQueueProcessor] TrapQueueProcessor: Trap successfully converted and sent to eventd 2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] V2TrapInformation: V2 trap numVars or pdu length: 11 2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] V2TrapInformation: v2 trap - trapInterface: /192.168.39.180 2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] V2TrapInformation: V2 trap first varbind value: 6d 5h 29m 13s 350ms 2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] V2TrapInformation: V2 trap first varbind value is of type TIMETICKS (correct) 2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] TrapIdentity: snmpTrapOID: .1.3.6.1.4.1.2323.1.13.7.1.4.1.3 2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] EventCreator: snmp trap [Generic=6, Specific=3, EnterpriseId=.1.3.6.1.4.1.2323.1.13.7.1.4.1] 2006-10-02 01:37:05,172 DEBUG [TrapQueueProcessor] EventConfData: Match found using key: EventKey [ id = [.1.3.6.1.4.1.2323.1.13.7.1.4.1] generic = [6] specific = [3] ] 2006-10-02 01:37:05,172 DEBUG [TrapQueueProcessor] TrapQueueProcessor: Trap successfully converted and sent to eventd --- cut --- event.xml --- cut --- id .1.3.6.1.4.1.2323.1.13.7.1.4.1 generic 6 specific 3 uei.opennms.org/vendor/alcatel/cms/systemAlarm ALCATEL-CMS-SYSTEM defined trap event: systemAlarm <p>This notification indicates that a System error type of alarm has occurred and some action needs to be taken to correct this error. </p><table> <tr><td><b> alarmId</b></td><td> %parm[#1]%;</td><td><p;></p></td;></tr> <tr><td><b> alarmSeverity</b></td><td> %parm[#2]%;</td><td><p;> none(0) critical(1) major(2) minor(3) informational(4) invalid(5) </p></td;></tr> <tr><td><b> alarmText</b></td><td> %parm[#3]%;</td><td><p;></p></td;></tr> <tr><td><b> alarmSource</b></td><td> %parm[#4]%;</td><td><p;></p></td;></tr> <tr><td><b> alarmTimestamp</b></td><td> %parm[#5]%;</td><td><p;></p></td;></tr> <tr><td><b> alarmAdditionalInfo</b></td><td> %parm[#6]%;</td><td><p;></p></td;></tr> <tr><td><b> alarmEventType</b></td><td> %parm[#7]%;</td><td><p;></p></td;></tr> <tr><td><b> alarmInstId</b></td><td> %parm[#8]%;</td><td><p;></p></td;></tr> <tr><td><b> id</b></td><td> %parm[#9]%;</td><td><p;></p></td;></tr></table> <p> systemAlarm trap received alarmId=%parm[#1]% alarmSeverity=%parm[#2]% alarmText=%parm[#3]% alarmSource=%parm[#4]% alarmTimestamp=%parm[#5]% alarmAdditionalInfo=%parm[#6]% alarmEventType=%parm[#7]% alarmInstId=%parm[#8]% id=%parm[#9]%</p> Indeterminate --- cut ---