elessar:~ ariela$ dispcal -v -m -gl -qh -H cinema Setting up the instrument Instrument Type: ColorMunki Serial Number: 2018587 Firmware version: 288 Chip ID: 01-adec371200001b Version string: 'colormunki FW V1.32 Build Nr. 1303' Calibration Ver.: 6 Production No.: 65745 Set instrument sensor to calibration position, and then hit any key to continue, or hit Esc or Q to abort: Calibration complete Place instrument on test window. Hit Esc or Q to give up, any other key to continue: Target white = native white point Target white brightness = native brightness Target black brightness = native brightness Target gamma = L* curve Commencing device calibration patch 6 of 6 Black = XYZ 0.25 0.25 0.38 Red = XYZ 58.19 30.33 1.58 Green = XYZ 56.90 109.62 11.07 Blue = XYZ 29.82 11.52 161.71 White = XYZ 144.90 151.49 173.69 patch 80 of 80 Initial native brightness target = 151.494521 cd/m^2 Target white value is XYZ 144.898856 151.494521 173.693423 Adjusted target black XYZ 0.24 0.25 0.29, Lab 1.50 0.00 0.00 Target black after min adjust: XYZ 0.310 0.324 0.371, Lab 1.930 0.000 0.000 Gamma curve input offset = 0.000000, output offset = 0.002137, power = 0.000000 Total Iteration 4, Final Samples = 96 Final Repeat threshold = 0.400000 Creating initial calibration curves... Doing iteration 1 with 12 sample points and repeat threshold of 1.131371 DE patch 12 of 12 Brightness error = 0.000000 cd/m^2 (is 151.433926, should be 151.433926) White point error = 0.000000 deltaE Maximum neutral error (@ 0.283220) = 1.071289 deltaE Average neutral error = 0.704950 deltaE Number of measurements taken = 22 Computing update to calibration curves... Doing iteration 2 with 24 sample points and repeat threshold of 0.800000 DE patch 24 of 24 Brightness error = 0.000000 cd/m^2 (is 151.370769, should be 151.370769) White point error = 0.000000 deltaE Maximum neutral error (@ 0.353123) = 0.798558 deltaE Average neutral error = 0.533175 deltaE Number of measurements taken = 58 Computing update to calibration curves... Doing iteration 3 with 48 sample points and repeat threshold of 0.565685 DE patch 48 of 48 Brightness error = 0.000000 cd/m^2 (is 151.490443, should be 151.490443) White point error = 0.000000 deltaE Maximum neutral error (@ 0.144028) = 1.054379 deltaE Average neutral error = 0.407290 deltaE Failed to meet target 0.565685 delta E, got worst case 1.054379 Number of measurements taken = 215 Computing update to calibration curves... Doing iteration 4 with 96 sample points and repeat threshold of 0.400000 DE patch 96 of 96 Brightness error = 0.000000 cd/m^2 (is 151.354389, should be 151.354389) White point error = 0.000000 deltaE Maximum neutral error (@ 0.069836) = 1.563194 deltaE Average neutral error = 0.415944 deltaE Failed to meet target 0.400000 delta E, got worst case 1.369969 Number of measurements taken = 808 The instrument can be removed from the screen. Written calibration file 'cinema.cal' elessar:~ ariela$ targen -v -w -d3 -g 32 cinema RGB test chart Compostie Grey steps = 32 Full spread patches = 836 Degree of adaptation: 0.100 Adaptation weights: Device = 0.935, Perceptual = 0.065, Curvature = 0.010 Perceptual cache resolution = 11 Acceleration grid res = 10 There are 32 unique fixed points to add (35 total fixed points) There are 801 far spread points to add Added 833/833 After seeding points: MinPoint = 5.358, Min = 4.925, Avg. = 8.814, Max = 11.293, 0.5 secs Re-seeding It 1: Maxmv = 0.049761, MinPoint = 5.358, Min = 3.498, Avg. = 8.849, Max = 11.493, 0.5 secs. Re-seeding It 2: Maxmv = 0.046361, MinPoint = 5.358, Min = 4.925, Avg. = 8.810, Max = 11.192, 0.5 secs. Re-seeding It 3: Maxmv = 0.034787, MinPoint = 5.358, Min = 4.925, Avg. = 8.759, Max = 10.997, 0.5 secs. Fixing up veronoi It 4: Maxmv = 0.021185, MinPoint = 5.358, Min = 4.925, Avg. = 8.730, Max = 10.740, 0.3 secs. Fixing up veronoi It 5: Maxmv = 0.010910, MinPoint = 5.358, Min = 4.925, Avg. = 8.716, Max = 10.652, 0.3 secs. Fixing up veronoi It 6: Maxmv = 0.000923, MinPoint = 5.358, Min = 4.925, Avg. = 8.715, Max = 10.661, 0.2 secs. After optimization: MinPoint = 5.358, Min = 4.925, Avg. = 8.715, Max = 10.661 Total number of patches = 836 Execution time = 2.780000 seconds elessar:~ ariela$ dispread -v -k cinema.cal -H cinema Number of patches = 836 Setting up the instrument Instrument Type: ColorMunki Serial Number: 2018587 Firmware version: 288 Chip ID: 01-adec371200001b Version string: 'colormunki FW V1.32 Build Nr. 1303' Calibration Ver.: 6 Production No.: 65745 Set instrument sensor to calibration position, and then hit any key to continue, or hit Esc or Q to abort: Calibration complete Place instrument on test window. Hit Esc or Q to give up, any other key to continue: patch 836 of 836 The instrument can be removed from the screen. Written 'cinema.ti3' elessar:~ ariela$ colprof -v -qh -al cinema No of test patches = 836 Estimating white point Approximate White point XYZ = 0.956325 1.000175 1.146475, Lab = 100.006766 -1.394119 -23.183315 Creating optimised per channel curves Initial White Point XYZ 0.956325 1.000175 1.146475, Lab 100.006766 -1.394119 -23.183315 About to optimise temporary matrix 100% About to optimise input curves and matrix 100% About to optimise output curves and matrix 100% About to optimise input curves and matrix again 100% About to optimise input, matrix and output together 100% About to adjust a and b output curves for white point About to create grid position input curves Create final clut from scattered data *************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************** Doing White point fine tune: Before fine tune, rel WP = XYZ 0.964069 0.999886 0.825962, Lab 99.995592 -0.003669 -0.093407 After fine tune, rel WP = XYZ 0.964200 1.000000 0.824900, Lab 100.000000 -0.000000 -0.000000 Creating fast inverse input lookups White point XYZ = 0.956284 1.000090 1.147966, Lab = 100.003498 -1.387242 -23.285674 Find black point Black point XYZ = 0.002699 0.002878 0.003563, Lab = 2.599287 -0.306548 -2.245240 Display Luminance = 151.750086 Done A to B table creation Setting up B to A table lookup Creating B to A tables Rev cache RAM = 1610 Mbytes There is 1 rev cache instance with 1610 Mbytes limit There are 2 rev cache instances with 805 Mbytes limit 100% Done B to A tables There is 1 rev cache instance with 1610 Mbytes limit Profile check complete, peak err = 1.734456, avg err = 0.356211, RMS = 0.435936 profcheck log: No of test patches = 836 Profile check complete, errors(CIEDE2000): max. = 1.029833, avg. = 0.156989, RMS = 0.193927 elessar:~ ariela$ dispcal -yl -r Set instrument sensor to calibration position, and then hit any key to continue, or hit Esc or Q to abort: Calibration complete Place instrument on test window. Hit Esc or Q to give up, any other key to continue: Current calibration response: Black level = 0.45 cd/m^2 White level = 162.14 cd/m^2 Aprox. gamma = 2.41 Contrast ratio = 357:1 White chromaticity coordinates 0.3088, 0.3231 White Correlated Color Temperature = 6777K, DE 2K to locus = 3.3 White Correlated Daylight Temperature = 6778K, DE 2K to locus = 1.5 White Visual Color Temperature = 6648K, DE 2K to locus = 3.1 White Visual Daylight Temperature = 6839K, DE 2K to locus = 1.5 The instrument can be removed from the screen.