iltsu@iltsu:~$ sudo smartctl -a /dev/hda smartctl version 5.32 Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: QUANTUM FIREBALL CR8.4A Serial Number: 828923539890 Firmware Version: A5U.0200 Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 4 ATA Standard is: ATA/ATAPI-4 T13 1153D revision 15 Local Time is: Sun Nov 26 12:39:28 2006 EET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 2) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 14) minutes. SMART Attributes Data Structure revision number: 9 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0029 100 100 020 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 081 077 020 Pre-fail Always - 2479 4 Start_Stop_Count 0x0032 100 100 008 Old_age Always - 220 5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail Always - 0 9 Power_On_Hours 0x0012 056 056 001 Old_age Always - 29238 11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 008 Old_age Always - 220 13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail Always - 0 199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Reserved offline Completed: electrical failure 70% 2 3288334938 Device does not support Selective Self Tests/Logging