;signalling=em_w ; ; All those in group 0 I'll use for outgoing calls ; ; ; For example, maybe we have some other channels ; which start out in a different context and use ; E & M signalling instead. ; ;context=remote ;sigalling=em ;channel => 15 ;channel => 16 ;signalling=em_w ; ; All those in group 0 I'll use for outgoing calls ; Strip most significant digit (9) before sending ; ;stripmsd=1 ;callerid=asreceived ;group=0 ;signalling=fxs_ls ;channel => 45 ;signalling=fxo_ls ;group=1 ;callerid="Joe Schmoe" <(256) 428-6131> ;channel => 25 ;callerid="Megan May" <(256) 428-6132> ;channel => 26 ;callerid="Suzy Queue" <(256) 428-6233> ;channel => 27 ;callerid="Larry Moe" <(256) 428-6234> ;channel => 28 ; ; Sample PRI (CPE) config: Specify the switchtype, the signalling as ; either pri_cpe or pri_net for CPE or Network termination, and generally ; you will want to create a single "group" for all channels of the PRI. ; ; switchtype = national ; signalling = pri_cpe ; group = 2 ; channel => 1-23 ; ; Used for distintive ring support for x100p. ; You can see the dringX patterns is to set any one of the dringXcontext fields ; and they will be printed on the console when an inbound call comes in. ; ;dring1=95,0,0 ;dring1context=internal1 ;dring2=325,95,0 ;dring2context=internal2 ; If no pattern is matched here is where we go. ;context=default ;channel => 1 signalling=fxo_ks channel=1 signalling=fxo_ks channel=2 ;context=analog1 signalling=fxs_ks callerid=asreceived immediate=no channel=3 group=1 ;context=analog2 signalling=fxs_ks callerid=asreceived immediate=no channel=4 group=1 ;signalling=fxo_ks ;channel=3 ;signalling=fxo_ks ;channel=4 Type :quit to exit Vim