smartctl version 5.36 [x86_64-mandriva-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: ST3160828AS Serial Number: 5MT47JTL Firmware Version: 8.04 User Capacity: 160,000,000,000 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 2 Local Time is: Tue Dec 5 09:56:42 2006 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 121) The previous self-test completed having the read element of the test failed. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 94) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 052 050 006 Pre-fail Always - 140006847 3 Spin_Up_Time 0x0003 099 099 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 16 5 Reallocated_Sector_Ct 0x0033 098 098 036 Pre-fail Always - 97 7 Seek_Error_Rate 0x000f 077 060 030 Pre-fail Always - 52418419 9 Power_On_Hours 0x0032 095 095 000 Old_age Always - 4756 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 16 194 Temperature_Celsius 0x0022 026 040 000 Old_age Always - 26 (Lifetime Min/Max 0/15) 195 Hardware_ECC_Recovered 0x001a 052 050 000 Old_age Always - 140006847 197 Current_Pending_Sector 0x0012 034 034 000 Old_age Always - 1293 198 Offline_Uncorrectable 0x0010 034 034 000 Old_age Offline - 1293 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 166 063 000 Old_age Always - 190 SMART Error Log Version: 1 ATA Error Count: 96 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 96 occurred at disk power-on lifetime: 4756 hours (198 days + 4 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c9 88 40 e1 Error: UNC at LBA = 0x014088c9 = 21006537 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 c9 88 40 e1 00 00:02:57.055 READ DMA c8 00 08 c9 88 40 e1 00 00:02:54.184 READ DMA c8 00 08 c9 88 40 e1 00 00:02:51.320 READ DMA c8 00 08 c9 88 40 e1 00 00:02:48.401 READ DMA c8 00 08 c9 88 40 e1 00 00:02:45.548 READ DMA Error 95 occurred at disk power-on lifetime: 4756 hours (198 days + 4 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c9 88 40 e1 Error: UNC at LBA = 0x014088c9 = 21006537 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 c9 88 40 e1 00 00:02:57.055 READ DMA c8 00 08 c9 88 40 e1 00 00:02:54.184 READ DMA c8 00 08 c9 88 40 e1 00 00:02:51.320 READ DMA c8 00 08 c9 88 40 e1 00 00:02:48.401 READ DMA c8 00 08 c9 88 40 e1 00 00:02:45.548 READ DMA Error 94 occurred at disk power-on lifetime: 4756 hours (198 days + 4 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c9 88 40 e1 Error: UNC at LBA = 0x014088c9 = 21006537 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 c9 88 40 e1 00 00:02:57.055 READ DMA c8 00 08 c9 88 40 e1 00 00:02:54.184 READ DMA c8 00 08 c9 88 40 e1 00 00:02:51.320 READ DMA c8 00 08 c9 88 40 e1 00 00:02:48.401 READ DMA c8 00 08 c9 88 40 e1 00 00:02:45.548 READ DMA Error 93 occurred at disk power-on lifetime: 4756 hours (198 days + 4 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c9 88 40 e1 Error: UNC at LBA = 0x014088c9 = 21006537 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 c9 88 40 e1 00 00:02:57.055 READ DMA c8 00 08 c9 88 40 e1 00 00:02:54.184 READ DMA c8 00 08 c9 88 40 e1 00 00:02:51.320 READ DMA c8 00 08 c9 88 40 e1 00 00:02:48.401 READ DMA c8 00 08 c9 88 40 e1 00 00:02:45.548 READ DMA Error 92 occurred at disk power-on lifetime: 4756 hours (198 days + 4 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c9 88 40 e1 Error: UNC at LBA = 0x014088c9 = 21006537 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 c9 88 40 e1 00 00:02:39.420 READ DMA c8 00 08 c9 88 40 e1 00 00:02:54.184 READ DMA c8 00 08 c9 88 40 e1 00 00:02:51.320 READ DMA c8 00 08 c9 88 40 e1 00 00:02:48.401 READ DMA c8 00 08 c9 88 40 e1 00 00:02:45.548 READ DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short captive Completed: read failure 90% 4756 21006537 # 2 Short captive Completed: read failure 90% 4755 3407959 # 3 Short captive Completed without error 00% 2157 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay