nicole@T3M4:~$ sudo smartctl -a /dev/hdc smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Maxtor DiamondMax Plus D740X family Device Model: MAXTOR 6L080L4 Serial Number: 664216713010 Firmware Version: A93.0500 User Capacity: 80.054.059.008 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 5 ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1 Local Time is: Tue Feb 6 14:54:15 2007 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 34) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 40) minutes. SMART Attributes Data Structure revision number: 11 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 063 062 020 Pre-fail Always - 4732 4 Start_Stop_Count 0x0032 095 095 008 Old_age Always - 3389 5 Reallocated_Sector_Ct 0x0033 098 036 020 Pre-fail Always - 14 7 Seek_Error_Rate 0x000b 100 001 023 Pre-fail Always In_the_past 0 9 Power_On_Hours 0x0012 090 090 001 Old_age Always - 7110 10 Spin_Retry_Count 0x0026 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 096 096 008 Old_age Always - 3266 13 Read_Soft_Error_Rate 0x000b 100 093 023 Pre-fail Always - 0 194 Temperature_Celsius 0x0022 079 073 042 Old_age Always - 56 195 Hardware_ECC_Recovered 0x001a 100 001 000 Old_age Always - 33689657 196 Reallocated_Event_Count 0x0010 100 253 020 Old_age Offline - 0 197 Current_Pending_Sector 0x0032 100 037 020 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x001a 001 001 000 Old_age Always - 19235 SMART Error Log Version: 1 ATA Error Count: 2198 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2198 occurred at disk power-on lifetime: 4563 hours (190 days + 3 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 18 64 f8 49 e2 Error: UNC 24 sectors at LBA = 0x0249f864 = 38402148 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 02 18 64 f8 49 e2 49 00:01:29.410 READ DMA c8 00 39 c9 8e 96 e0 96 00:01:29.400 READ DMA c8 00 50 ff c0 94 e0 94 00:01:29.394 READ DMA ca 00 08 8f 49 90 e0 90 00:01:29.393 WRITE DMA ca 00 08 17 ac 7c e0 7c 00:01:29.393 WRITE DMA Error 2197 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 01 e3 c6 04 f0 Error: UNC at LBA = 0x0004c6e3 = 313059 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 40 00 01 e3 c6 04 f0 04 00:02:03.389 READ VERIFY SECTOR(S) 40 00 02 e5 c6 04 f0 04 00:02:03.371 READ VERIFY SECTOR(S) c8 00 01 00 00 00 f0 00 00:02:03.371 READ DMA 40 00 02 e3 c6 04 f0 04 00:01:58.363 READ VERIFY SECTOR(S) c8 00 01 00 00 00 f0 00 00:01:58.362 READ DMA Error 2196 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 02 e3 c6 04 f0 Error: UNC at LBA = 0x0004c6e3 = 313059 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 40 00 02 e3 c6 04 f0 04 00:01:58.363 READ VERIFY SECTOR(S) c8 00 01 00 00 00 f0 00 00:01:58.362 READ DMA 40 00 04 e3 c6 04 f0 04 00:01:53.352 READ VERIFY SECTOR(S) 40 00 04 df c6 04 f0 04 00:01:53.352 READ VERIFY SECTOR(S) c8 00 01 3d 26 9c f0 9c 00:01:53.241 READ DMA Error 2195 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 04 e3 c6 04 f0 Error: UNC at LBA = 0x0004c6e3 = 313059 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 40 00 04 e3 c6 04 f0 04 00:01:53.352 READ VERIFY SECTOR(S) 40 00 04 df c6 04 f0 04 00:01:53.352 READ VERIFY SECTOR(S) c8 00 01 3d 26 9c f0 9c 00:01:53.241 READ DMA 40 00 08 e7 c6 04 f0 04 00:01:53.196 READ VERIFY SECTOR(S) c8 00 01 00 00 00 f0 00 00:01:53.196 READ DMA Error 2194 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 04 e3 c6 04 f0 Error: UNC at LBA = 0x0004c6e3 = 313059 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 40 00 08 df c6 04 f0 04 00:01:48.189 READ VERIFY SECTOR(S) 40 00 10 ef c6 04 f0 04 00:01:48.175 READ VERIFY SECTOR(S) c8 00 01 00 00 00 f0 00 00:01:48.171 READ DMA 40 00 10 df c6 04 f0 04 00:01:43.155 READ VERIFY SECTOR(S) c8 00 01 00 00 00 f0 00 00:01:43.154 READ DMA SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Device does not support Selective Self Tests/Logging