Host configuration Using a NIC versus using an iSCSI HBA All hosts in an IP SAN can utilize a standard IEEE NIC; however, an iSCSI HBA should be used for overall better performance or if booting from the SAN. A host can have one or more 10/100/1000 NICs or 1 Gb/s iSCSI HBAs. If the customer has a host application with substantial I/O requirements, then an iSCSI HBA should be considered. As a general rule, the iSCSI HBA will perform better than a standard 10/100/1000 NIC due to the iSCSI HBA’s TOE, which handles the processing of the TCP/IP frames of the iSCSI packets. For hosts that do not have a TOE, the host’s CPU(s) will process these frames, potentially impacting performance. A single NIC or iSCSI HBA is required for the iSCSI solution; however, two NICs or HBAs are strongly recommended with the use of PowerPath® or other host failover software to ensure host connectivity through path failures. PowerPath can also provide load balancing, finetuning and balancing the I/O loads across all available paths between the host and the storage system.