=== START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 92) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 093 088 006 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 100 096 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 88 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 073 060 030 Pre-fail Always - 30246569931 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 1821 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 275 187 Unknown_Attribute 0x0032 098 098 000 Old_age Always - 2 189 Unknown_Attribute 0x003a 100 100 000 Old_age Always - 0 190 Temperature_Celsius 0x0022 064 058 045 Old_age Always - 606339108 194 Temperature_Celsius 0x0022 036 042 000 Old_age Always - 36 (Lifetime Min/Max 0/23) 195 Hardware_ECC_Recovered 0x001a 070 054 000 Old_age Always - 15 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 1 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 1 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 10 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 10 occurred at disk power-on lifetime: 1555 hours (64 days + 19 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c0 1e 04 e0 Error: UNC at LBA = 0x00041ec0 = 270016 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 70 bd 1e 04 e0 00 00:00:54.067 READ DMA EXT 25 00 78 b5 1e 04 e0 00 00:00:54.066 READ DMA EXT 25 00 08 ad 1e 04 e0 00 00:00:54.065 READ DMA EXT 25 00 f8 8d 1d 04 e0 00 00:00:54.063 READ DMA EXT 25 00 08 85 1d 04 e0 00 00:00:55.826 READ DMA EXT Error 9 occurred at disk power-on lifetime: 1555 hours (64 days + 19 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c0 1e 04 e0 Error: UNC at LBA = 0x00041ec0 = 270016 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 78 b5 1e 04 e0 00 00:00:54.067 READ DMA EXT 25 00 08 ad 1e 04 e0 00 00:00:54.066 READ DMA EXT 25 00 f8 8d 1d 04 e0 00 00:00:54.065 READ DMA EXT 25 00 08 85 1d 04 e0 00 00:00:54.063 READ DMA EXT 25 00 00 d5 1a 04 e0 00 00:00:54.062 READ DMA EXT Error 8 occurred at disk power-on lifetime: 1 hours (0 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 00 00 00 00 e0 Error: ICRC, ABRT at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 03 01 00 00 00 e0 00 00:04:02.766 READ DMA EXT 29 03 01 00 00 00 e0 00 00:04:02.744 READ MULTIPLE EXT ef 03 45 01 10 00 a0 02 00:04:02.744 SET FEATURES [Set transfer mode] ef 03 0c 01 10 00 a0 02 00:04:02.744 SET FEATURES [Set transfer mode] c6 00 10 01 00 00 a0 02 00:04:02.743 SET MULTIPLE MODE Error 7 occurred at disk power-on lifetime: 1 hours (0 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 00 00 00 00 e0 Error: ICRC, ABRT at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 01 00 00 00 e0 00 00:03:52.708 READ DMA EXT ec 00 00 00 00 00 a0 00 00:03:52.708 IDENTIFY DEVICE b0 d8 00 00 4f c2 a0 00 00:03:52.701 SMART ENABLE OPERATIONS b0 da 00 00 4f c2 a0 00 00:03:42.706 SMART RETURN STATUS b0 d8 00 00 4f c2 a0 00 00:03:42.696 SMART ENABLE OPERATIONS Error 6 occurred at disk power-on lifetime: 1 hours (0 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 00 00 00 00 e0 Error: ICRC, ABRT at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 01 00 00 00 e0 00 00:03:32.638 READ DMA EXT ec 00 00 00 00 00 a0 00 00:03:32.638 IDENTIFY DEVICE 29 03 01 00 00 00 e0 00 00:03:32.630 READ MULTIPLE EXT ef 03 45 01 10 00 a0 02 00:03:42.706 SET FEATURES [Set transfer mode] ef 03 0c 01 10 00 a0 02 00:03:42.696 SET FEATURES [Set transfer mode] SMART Self-test log structure revision number 1 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.