smartctl version 5.37 [x86_64-suse-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: WDC WD3200AAKS-00SBA0 Serial Number: WD-WMAPZ0464810 Firmware Version: 12.01B01 User Capacity: 320,072,933,376 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Wed Nov 21 17:23:40 2007 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (8400) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 106) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 159 157 021 Pre-fail Always - 5041 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 260 5 Reallocated_Sector_Ct 0x0033 199 199 140 Pre-fail Always - 2 7 Seek_Error_Rate 0x000e 200 200 051 Old_age Always - 0 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 945 10 Spin_Retry_Count 0x0012 100 100 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0012 100 100 051 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 179 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 17 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 260 194 Temperature_Celsius 0x0022 112 097 000 Old_age Always - 35 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 2 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline - 0 SMART Error Log Version: 1 ATA Error Count: 22 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 22 occurred at disk power-on lifetime: 925 hours (38 days + 13 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 01 0a ba 49 e0 Error: UNC at LBA = 0x0049ba0a = 4831754 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 42 ff 01 0a ba 49 05 00 01:11:18.471 READ VERIFY SECTOR(S) EXT 25 ff 01 00 00 00 00 00 01:11:18.471 READ DMA EXT 42 ff 01 09 ba 49 05 00 01:11:18.471 READ VERIFY SECTOR(S) EXT 42 ff 02 0d ba 49 05 00 01:11:18.461 READ VERIFY SECTOR(S) EXT 25 ff 01 00 00 00 00 00 01:11:18.461 READ DMA EXT Error 21 occurred at disk power-on lifetime: 925 hours (38 days + 13 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 02 0b ba 49 e0 Error: UNC at LBA = 0x0049ba0b = 4831755 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 42 ff 02 0b ba 49 05 00 01:11:15.546 READ VERIFY SECTOR(S) EXT 25 ff 01 00 00 00 00 00 01:11:15.546 READ DMA EXT 42 ff 02 09 ba 49 05 00 01:11:12.907 READ VERIFY SECTOR(S) EXT 42 ff 02 07 ba 49 05 00 01:11:12.907 READ VERIFY SECTOR(S) EXT 25 ff 01 00 00 00 00 00 01:11:12.907 READ DMA EXT Error 20 occurred at disk power-on lifetime: 925 hours (38 days + 13 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 02 09 ba 49 e0 Error: UNC at LBA = 0x0049ba09 = 4831753 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 42 ff 02 09 ba 49 05 00 01:11:12.907 READ VERIFY SECTOR(S) EXT 42 ff 02 07 ba 49 05 00 01:11:12.907 READ VERIFY SECTOR(S) EXT 25 ff 01 00 00 00 00 00 01:11:12.907 READ DMA EXT 42 ff 04 0b ba 49 05 00 01:11:10.260 READ VERIFY SECTOR(S) EXT 25 ff 01 00 00 00 00 00 01:11:10.260 READ DMA EXT Error 19 occurred at disk power-on lifetime: 925 hours (38 days + 13 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 04 0b ba 49 e0 Error: UNC at LBA = 0x0049ba0b = 4831755 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 42 ff 04 0b ba 49 05 00 01:11:10.260 READ VERIFY SECTOR(S) EXT 25 ff 01 00 00 00 00 00 01:11:10.260 READ DMA EXT 42 ff 04 07 ba 49 05 00 01:11:07.489 READ VERIFY SECTOR(S) EXT 25 ff 01 00 00 00 00 00 01:11:07.489 READ DMA EXT 42 ff 08 07 ba 49 05 00 01:11:04.577 READ VERIFY SECTOR(S) EXT Error 18 occurred at disk power-on lifetime: 925 hours (38 days + 13 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 04 07 ba 49 e0 Error: UNC at LBA = 0x0049ba07 = 4831751 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 42 ff 04 07 ba 49 05 00 01:11:07.489 READ VERIFY SECTOR(S) EXT 25 ff 01 00 00 00 00 00 01:11:07.489 READ DMA EXT 42 ff 08 07 ba 49 05 00 01:11:04.577 READ VERIFY SECTOR(S) EXT 42 ff 08 ff b9 49 05 00 01:11:04.577 READ VERIFY SECTOR(S) EXT 42 ff 10 0f ba 49 05 00 01:11:04.566 READ VERIFY SECTOR(S) EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 931 - # 2 Short offline Completed without error 00% 930 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.