athlon mnt # smartctl -a /dev/hdd smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Maxtor DiamondMax Plus D740X family Device Model: MAXTOR 6L040J2 Serial Number: 662215842583 Firmware Version: AR1.0500 User Capacity: 40,027,029,504 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 5 ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1 Local Time is: Fri Jul 14 18:34:39 2006 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 34) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 21) minutes. SMART Attributes Data Structure revision number: 11 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 082 080 020 Pre-fail Always - 2286 4 Start_Stop_Count 0x0032 093 093 008 Old_age Always - 4805 5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail Always - 2 7 Seek_Error_Rate 0x000b 100 085 023 Pre-fail Always - 0 9 Power_On_Hours 0x0012 078 078 001 Old_age Always - 14802 10 Spin_Retry_Count 0x0026 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 093 093 008 Old_age Always - 4706 13 Read_Soft_Error_Rate 0x000b 100 093 023 Pre-fail Always - 0 194 Temperature_Celsius 0x0022 087 080 042 Old_age Always - 35 195 Hardware_ECC_Recovered 0x001a 100 013 000 Old_age Always - 5204625 196 Reallocated_Event_Count 0x0010 100 253 020 Old_age Offline - 0 197 Current_Pending_Sector 0x0032 100 100 020 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 674 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 674 occurred at disk power-on lifetime: 3080 hours (128 days + 8 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 d1 01 6e 5d 7e f0 Error: UNC 1 sectors at LBA = 0x007e5d6e = 8281454 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 01 6e 5d 7e f0 7e 00:05:25.085 READ DMA c8 00 02 6d 5d 7e f0 7e 00:05:19.943 READ DMA c8 00 03 6c 5d 7e f0 7e 00:05:14.801 READ DMA c8 00 04 6b 5d 7e f0 7e 00:05:09.660 READ DMA c8 00 05 6a 5d 7e f0 7e 00:05:04.518 READ DMA Error 673 occurred at disk power-on lifetime: 3080 hours (128 days + 8 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 01 6e 5d 7e f0 Error: UNC 1 sectors at LBA = 0x007e5d6e = 8281454 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 02 6d 5d 7e f0 7e 00:05:19.943 READ DMA c8 00 03 6c 5d 7e f0 7e 00:05:14.801 READ DMA c8 00 04 6b 5d 7e f0 7e 00:05:09.660 READ DMA c8 00 05 6a 5d 7e f0 7e 00:05:04.518 READ DMA c8 00 06 69 5d 7e f0 7e 00:04:59.376 READ DMA Error 672 occurred at disk power-on lifetime: 3080 hours (128 days + 8 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 01 6e 5d 7e f0 Error: UNC 1 sectors at LBA = 0x007e5d6e = 8281454 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 03 6c 5d 7e f0 7e 00:05:14.801 READ DMA c8 00 04 6b 5d 7e f0 7e 00:05:09.660 READ DMA c8 00 05 6a 5d 7e f0 7e 00:05:04.518 READ DMA c8 00 06 69 5d 7e f0 7e 00:04:59.376 READ DMA c8 00 07 68 5d 7e f0 7e 00:04:54.235 READ DMA Error 671 occurred at disk power-on lifetime: 3080 hours (128 days + 8 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 01 6e 5d 7e f0 Error: UNC 1 sectors at LBA = 0x007e5d6e = 8281454 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 04 6b 5d 7e f0 7e 00:05:09.660 READ DMA c8 00 05 6a 5d 7e f0 7e 00:05:04.518 READ DMA c8 00 06 69 5d 7e f0 7e 00:04:59.376 READ DMA c8 00 07 68 5d 7e f0 7e 00:04:54.235 READ DMA c8 00 08 67 5d 7e f0 7e 00:04:49.096 READ DMA Error 670 occurred at disk power-on lifetime: 3080 hours (128 days + 8 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 01 6e 5d 7e f0 Error: UNC 1 sectors at LBA = 0x007e5d6e = 8281454 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 6a 5d 7e f0 7e 00:05:04.518 READ DMA c8 00 06 69 5d 7e f0 7e 00:04:59.376 READ DMA c8 00 07 68 5d 7e f0 7e 00:04:54.235 READ DMA c8 00 08 67 5d 7e f0 7e 00:04:49.096 READ DMA c8 00 01 5e 29 00 f0 00 00:04:49.060 READ DMA SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Device does not support Selective Self Tests/Logging