boot from a DOS disk, I used a Windows XP MS-DOS startup disk - at the prompt type: DosFlash r DFA0 1 a0 1 4 orig.bin 0 - press return - DosFlash16 will ask you if you wanna resend the mtk vendor intro cmd, press Yes - after you pressed Yes the drive status is shown on the screen, it's something like 0x7F, this will change during the next few steps - turn on the BenQ psu and wait 2 or more seconds, status changes between 0x51 and 0xD1 - turn off the BenQ psu and wait 2 or more seconds, status will stay at 0xD1 - turn on the BenQ psu, you should get a good drive status 0x73 and flashing should start - this worked only one time after the computer is powered on or resetted for me - writing and erasing works the same way - for erasing type: DosFlash e DFA0 1 a0 1 4 C7 0 (C7 is the sector erase opcode for the BenQ flash, if you need to erase another drive, lookup the value in the datasheet or DosFlash.typ) - for writing type: DosFlash w DFA0 1 a0 1 4 ix14.bin 0