smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint P80 series Device Model: SAMSUNG SP1213C Serial Number: 0696J1FX502982 Firmware Version: SV100-27 User Capacity: 120,060,444,672 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 0 Local Time is: Sun Apr 13 22:50:47 2008 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (5040) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 84) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 1 3 Spin_Up_Time 0x0007 065 054 000 Pre-fail Always - 5952 4 Start_Stop_Count 0x0032 093 093 000 Old_age Always - 7244 5 Reallocated_Sector_Ct 0x0033 100 100 011 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 000 Pre-fail Offline - 0 9 Power_On_Half_Minutes 0x0032 099 099 000 Old_age Always - 5835h+41m 10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 096 096 000 Old_age Always - 4870 194 Temperature_Celsius 0x0022 178 088 000 Old_age Always - 20 195 Hardware_ECC_Recovered 0x001a 001 001 000 Old_age Always - 12062630 196 Reallocated_Event_Count 0x0012 100 100 000 Old_age Always - 2 197 Current_Pending_Sector 0x0033 100 100 011 Pre-fail Always - 0 198 Offline_Uncorrectable 0x0030 100 100 011 Old_age Offline - 2 199 UDMA_CRC_Error_Count 0x0036 200 199 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 201 Soft_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 SMART Error Log Version: 1 ATA Error Count: 19 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 19 occurred at disk power-on lifetime: 4263 hours (177 days + 15 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 38 90 ec 0e e0 Error: ICRC, ABRT 56 sectors at LBA = 0x000eec90 = 978064 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 38 90 ec 0e e0 00 05:08:21.250 READ DMA c8 00 08 40 e7 13 e0 00 05:08:21.250 READ DMA c8 00 18 10 e7 13 e0 00 05:08:21.250 READ DMA c8 00 08 08 b5 13 e0 00 05:08:21.250 READ DMA c8 00 30 d0 b4 13 e0 00 05:08:21.250 READ DMA Error 18 occurred at disk power-on lifetime: 3082 hours (128 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 08 e6 4b e3 e1 Error: ICRC, ABRT 8 sectors at LBA = 0x01e34be6 = 31673318 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 e6 4b e3 e1 00 01:01:12.438 READ DMA c8 00 08 46 3b e3 e1 00 01:01:12.438 READ DMA c8 00 40 a6 42 e3 e1 00 01:01:12.438 READ DMA c8 00 08 7e 43 e3 e1 00 01:01:12.438 READ DMA c8 00 40 a6 7a e3 e1 00 01:01:12.438 READ DMA Error 17 occurred at disk power-on lifetime: 3060 hours (127 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 08 66 94 e7 e1 Error: ICRC, ABRT 8 sectors at LBA = 0x01e79466 = 31954022 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 66 94 e7 e1 00 03:23:44.688 READ DMA c8 00 10 96 60 e7 e1 00 03:23:44.688 READ DMA c8 00 08 86 60 e7 e1 00 03:23:44.688 READ DMA c8 00 10 a6 e2 e6 e1 00 03:23:44.688 READ DMA c8 00 08 be e2 e6 e1 00 03:23:44.688 READ DMA Error 16 occurred at disk power-on lifetime: 2898 hours (120 days + 18 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 04 3f 2f 00 e0 Error: ICRC, ABRT 4 sectors at LBA = 0x00002f3f = 12095 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 da 04 3f 2f 00 e0 00 00:00:29.125 READ DMA c8 da 08 1f 01 00 e0 00 00:00:29.125 READ DMA c8 da 10 bf 00 00 e0 00 00:00:29.125 READ DMA c8 da 01 40 00 00 e0 00 00:00:29.125 READ DMA c8 da 01 00 00 00 e0 00 00:00:29.125 READ DMA Error 15 occurred at disk power-on lifetime: 1914 hours (79 days + 18 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 3f 4a 83 80 e0 Error: ICRC, ABRT 63 sectors at LBA = 0x0080834a = 8422218 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 da 3f 4a 83 80 e0 00 00:00:47.875 READ DMA c8 da 3f 4b 73 80 e0 00 00:00:47.875 READ DMA c8 da 3f 0c 73 80 e0 00 00:00:47.875 READ DMA c8 da 3f 00 00 00 e0 00 00:00:47.875 READ DMA c8 da 70 7c f3 8e e3 00 00:00:47.813 READ DMA SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Device does not support Selective Self Tests/Logging